  1. Measure the pressure of high pressure line by measuring voltage output between NO. 1 and NO. 2 terminals.
    Fig 1: Measuring Voltage Output Between No. 1 And No. 2 Terminals
    G11818479Courtesy of KIA MOTORS AMERICA, INC.
  2. Inspect the voltage value whether it is sufficient to be regular value or not.
    Fig 2: Voltage Value Graph
    G11818480Courtesy of KIA MOTORS AMERICA, INC.

    Voltage =  0.00878835 * Pressure + 0.5[PSIA]

  3. If the measured voltage value is not specification, replace the A/C pressure transducer.