LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2016 >> Optima SX Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Hydraulic System (HEV)) >> Oil Pump Unit (OPU) >> Schematic Diagrams >> OPU Terminal input/output signal >> B

OPU Terminal input/output signal: B

WARNING: This page is about a different variant/trim than selected.
Pin Description Condition Input/output value
Type Level
1 Battery power (+) IG Off DC Voltage Battery Voltage
After startup Battery Voltage
Startup Off(dark current) Max 5mA
2 Battery power(+) IG Off DC Voltage Battery Voltage
After startup Battery Voltage
Startup Off(dark current) Max 5mA
3 CAN Low IG Off Pulse -
Recessive 2.0 ~ 3.0 V
Dominant 0.5~2.25 V
4 OPU status signal IG Off Pulse -
After startup (Low) Max. 1.0V
After startup (High) 0V/Battery voltage level
9V < Battery voltage level <16V
5 Hall sensor ground IG Off DC Voltage -
IG On Max. 0.5V
6 Hall sensor power(+5V) IG Off DC Voltage -
IG On 5.0V ± 0.5V
7 IG_Key IG Off DC Voltage -
IG On Battery Voltage
9 CAN High IG Off Pulse -
Recessive 2.0 ~ 3.0 V
Dominant 2.75~4.5 V
11 Hall signal A IG Off Pulse -
After startup (Low) Max. 0.5V
After startup (High) 5.0V ± 0.5V
12 Main relay operation signal IG Off DC Voltage -
After startup(Disable) Battery voltage level
After startup (Enable) Battery voltage level
13 Ground IG Off DC Voltage -
IG On Max. 0.5V
14 Ground IG Off DC Voltage -
IG On Max. 0.5V
15 Motor speed command signal IG Off Pulse -
After startup (Low) Max. 0.5V
After startup (High) 0V/Battery voltage level
9V < Battery voltage level <16V
17 Hall signal B IG Off Pulse -
After startup (Low) Max. 0.5V
After startup (High) 5.0V ± 0.5V
18 Hall signal C IG Off Pulse -
After startup (Low) Max. 0.5V
After startup (High) 5.0V ± 0.5V