Pin Description Condition Input/output value
Type Level
1 Main relay power IG Off DC Voltage -
After startup (Disable) Max. 0.5V
After startup (Enable) Battery Voltage
2 Ground IG Off DC Voltage -
IG On Max. 0.5V
3 Motor phase power (U) IG Off PWM -
After startup (Disable) Max. 0.5V
After startup (Enable) Battery Voltage
4 Motor phase power (V) IG Off PWM -
After startup (Disable) Max. 0.5V
After startup (Enable) Battery Voltage
5 Motor phase power (W) IG Off PWM -
After startup (Disable) Max. 0.5V
After startup (Enable) Battery Voltage