Radiator Leakage Test
WARNING: This page is about a different variant/trim than selected.
- Wait until engine is cool, then carefully remove the inverter reservoir cap and fill the reservoir with coolant, then install it on the pressure tester.
- Apply a pressure tester to the reservoir and apply a pressure of 93.16 ~ 122.58kPa (0.95 ~ 1.25kgf/cm2 , 13.51 ~ 17.78psi).
- Inspect for inverter coolant leaks and a drop in pressure.
- Remove the tester and reinstall the inverter reservoir cap.