DTC Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
- Check Fuel Tank Pressure (FTP) with Canister Control Valve (CCV) and Purge Control Solenoid Valve (PCSV) closed after the P0455 monitor
|
- Leakage in each hose/fuel filler pipe
- Leakage in CCV/Canister/Fuel tank/Fuel Filler Cap
|
| Enable Conditions |
- Canister Control Valve (CCV) Close
- Purge Control Solenoid Valve (PCSV) Close
- Common conditions for evap. system monitoring
- Time after engine start greater than 130s
- Engine Coolant Temperature (ECT) at start greater than 4°C (39.2°F) and less than 50°C (122°F)
- Ambient Air Temperature (AAT) greater than 0°C (32°F) and less than 42°C (107.6°F)
- BARO greater than 74.5kPa (0.745bar/10.8psi)
- Fuel level greater than 15% and less than 85%
- Purge active time greater than 10s
- Closed loop fuel control On
- Accel. pedal = 0%
- Vehicle speed = 0km (0mph)
- No disabling faults present
- Refueling condition Not detected (Fuel Tank Pressure over 3hPa and Filtered FTP over 0.5hPa)
- Intake manifold pressure/BARO greater than 0.6
|
| Threshold value |
- Tank pressure gradient greater than 44-60 Pa/s
|
| Diagnosis Time |
|
| MIL On Condition |
|