Monitor GDS Data
- Connect Data Link Connector (DLC) to GDS.
- Check the "Current Data" about related DTC with GDS.
- Monitor displayed parameter below with GDS while performing "EPB releasing & EPB applying" in "Actuation Test". (dual mode)
- Is DTC status displayed as Present?
YES
- Fault might be intermittent caused by poor contact in the sensor's and/or ECU's connector or was repaired and ECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Go to "TERMINAL AND CONNECTOR INSPECTION " procedure.