| DTC Strategy |
- Operation duration and current monitoring
|
- Poor connection or damaged wiring
- LH motor open or short
- LH motor
- EPB ECU
|
| Enable condition |
- Normal battery voltage
- Ignition "ON"
- EPB operating control (On/Off)
|
| Threshold value |
- Actuator driving is continued for over 15 sec. to applying direction
- Actuator driving is continued for over 7 sec. to releasing direction
- The detection time of actuator is increased in Diagnose Mode
|
| Warning Indicator Lamp Status |
- Warning Indicator Lamp "ON"
- Indicator status lamp "ON"
|
| Fail Safe |
|
| Reset Condition |
- Ignition "OFF" and then "ON"
|