| DTC Strategy |
|
- Faulty pressure sensor
- Air in the hydraulic system
- Brake fluid leakage
- Foreign material in brake fluid
- Faulty pump (or motor)
- Faulty Valve
- Exceedingly Frequent Braking
- Empty Brake Fluid Reservoir
|
| Case 1 |
Enable Conditions |
- In case of Pressure sensor offset that calculated during driving is over 15bar
- ECU compare the deviation pressure signal [HPA, BCP, ESC MCP]. If the change of pressure signal is discordant, ECU detect failure.
|
| Fail Safe |
- EBD warning lamp is activated and buzzer is not activated.
- "Check Brake!" message is displayed on LCD.
|
| Case 2 |
Enable Conditions |
- In the case of HPA pressure is under specific pressure
- If HPA charging continues for more than 35sec, ECU detects failure.
- In case of HPA pressure stick during HPA charing, ECU detects failure
|
| Fail Safe |
- EBD warning lamp and buzzer are activated.
- "Check Brake!" message is displayed on LCD.
|