LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2012 >> Optima Hybrid >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Active Hydraulic Booster (AHB) System - HEV >> Description and Operation >> Description >> HPU connector input/output

HPU connector input/output

Fig 1: Identifying HPU Connector Terminals (Input/Output)
G08308660Courtesy of KIA MOTORS AMERICA, INC.
Connector Terminal Specification Remark
No Description
3 IGNITION1(+) Over voltage range: 16.0 ± 0.5V
Operating voltage range: 9.0 ± 0.5V < V < 16.0 ± 0.5V
Low voltage range: 8.0 ± 0.5V < V < 9.5 ± 0.5V
Max. current: I < 50mA
 
2 POS. BATTERY 1. (SOLENOID) Operating voltage range: 9.0 ± 0.5V < V < 16.0 ± 0.5V
Max. current: I < 500mA
Max. current: I < 15A
Max. leakage current: I < 0.3mA
No AHB Control
In AHB Control
1 POS. BATTERY 2. (MOTOR) Operating voltage range: 9.0 ± 0.5V < V < 16.0 ± 0.5V
Rush current: I < 110A
Max. current: I < 40A
Max. leakage current: I < 0.2mA
Rush current
Continuus current
26 GROUND Rated current: I < 550mA
Max. current: I < 15A
In AHB Control
25 PUMP MOTOR GROUND Rush current: I < 110A
Max. current: I < 40A
In AHB Control
13 CAN BUS LINE(LOW) Max. Input current: I < 10mA  
6 CAN BUS LINE(HIGH)
20 CAN SENSOR LINE (HIGH) Max. input current: I < 10mA  
12 CAN SENSOR LINE (LOW)
14 BRAKE LIGHT SWITCH Input voltage (Low): V < 2V
Input voltage (High): V > 6V
Max. Input current: I < 3mA (@12.8V)
 
21 DOOR SWITCH(DRIVER)
18 PEDAL STROKE SENSOR POWER Max. Output current: I < 30mA
Max. Output voltage: 4.75V ≤ V ≤ 5.255V
 
10 PEDAL STROKE SENSOR GROUND Max. Output current: I < 30mA  
8 PEDAL STROKE SENSOR GROUND Min. Output voltage: 0.75 ± 0.05V
Max. Output voltage: 4.1 ± 0.3V