Home >> Kia >> 2008 >> Rio Base, Automatic >> Repair and Diagnosis (Single Page) >> Engine Mechanical >> Auxiliary Emission Control Systems >> Evaporative Emission Control System >> Evaporative (EVAP) Canister Purge Solenoid Valve >> Inspection

Evaporative (EVAP) Canister Purge Solenoid Valve: Inspection

NOTE: When disconnecting the vacuum hose, make an identification mark on it so that it can be reconnected to its original position.
  1. Disconnect the vacuum hose from the solenoid valve.
  2. Detach the harness connector.
  3. Connect a vacuum pump to the nipple to which the red-striped vacuum hose was connected.
  4. Apply vacuum and check when voltage is applied to the PCSV and when the voltage is discontinued.
    VOLTAGE REFERENCE

    Battery voltage Normal condition
    When applied Vacuum is released
    When discontinued Vacuum is maintained
  5. Measure the resistance between the terminals of the solenoid valve.

    PCSV coil resistance (Ω): 16.0 Ω at 20°C (68°F)