Shift Solenoid: Description and Operation

SOLENOID VALVE

DESCRIPTION

ACTUATORS

Solenoid Valve for Pressure Control
^ Sensor type: Normal open 3-way
^ Operating temperature: -30°C-130°C(-22°F-266°F)
^ Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
^ Internal resistance: 3.0 ± 0.5 Ohms (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ohms (VFS)
^ Surge voltage: 56 V (Except VFS)




Location:




Solenoid Valves Schedule: