Loaded Condition
- Start engine.
- Depress brake pedal with a force of 44 lb.ft (196 N.m, 20 kg.m).
- With brake pedal depressed, stop engine when vacuum gauge reaches 19.7 inHg (500 mmHg).
- Observe vacuum gauge for 15 seconds. If gauge shows 18.7-19.7 inHg (475-500 mmHg), unit is operating.