TERMINAL VOLTAGE CONTINUITY INSPECTION
1. Remove console.

NOTICE: Disconnect connector C307 when checking continuity between terminal 2 (harness side) and ground.

2. Shift selector lever to P range, and check terminal voltages and continuity, referring to chart.

Fig. 15 Shift Lock Actuator Terminal Identification:





3. If not as specified, repair wire harness and/or replace shift-lock actuator.
4. Install console.








5. Verify correct operation of shift-lock system.