Home >> Kia >> 2000 >> Spectra GS, Standard >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Controls - Self-Diagnostics - SEPHIA & Spectra >> Diagnostic Trouble Codes >> DTC P1507: Idle Air Control (IAC) Valve Closing Coil Signal Low, Or DTC P1508: Idle Air Control (IAC) Valve Closing Coil Signal High >> Procedure

DTC P1507: Idle Air Control (IAC) Valve Closing Coil Signal Low, Or DTC P1508: Idle Air Control (IAC) Valve Closing Coil Signal High: Procedure

  1. Turn ignition off. Disconnect IAC valve 3-pin connector. Turn ignition on. Measure voltage between ground and IAC valve harness connector terminal No. 2 (Red/Yellow wire). See Figure . If battery voltage exists, go to next step. If battery voltage does not exist, repair open in Red/Yellow wire between engine compartment fuse/relay box and IAC valve.
  2. Turn ignition off. Disconnect ECM 88-pin connector. Measure resistance of White/Yellow wire between IAC valve harness connector terminal No. 1 and ECM harness connector terminal No. 2. See Figure and Figure . If code is DTC P1507 and resistance is less than one ohm, go to next step. If code is DTC P1508 and resistance is less than one ohm, go to step  4 . If resistance is not as specified, repair open in White/Yellow wire between IAC valve and ECM.
  3. Check for continuity between ground and ECM harness connector terminal No. 2 (White/Yellow wire). If continuity does not exist, go to step  5 . If continuity exists, repair short to ground in White/Yellow wire between IAC valve and ECM.
  4. Turn ignition on. Check for voltage between ground and ECM harness connector terminal No. 2 (White/Yellow wire). If voltage does not exist, go to next step. If voltage exists, repair short to power in White/Yellow wire between IAC valve and ECM.
  5. Turn ignition off. Measure resistance between IAC valve harness connector terminals No. 1 and 2 (White/Yellow wire and Red/Yellow wire - component side). See Figure . Also, measure resistance between IAC valve harness connector terminals No. 2 and 3 (Red/Yellow wire and White/Green wire - component side). Resistance should be 14.5-16.5 ohms at 68°F (20°C). If resistance is not as specified, replace IAC valve. If resistance is as specified, check connectors for loose, damaged or corroded terminals. If problem exists, repair connector as necessary.