Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- CHECK FOR AN ACTIVE CONDITION
- Turn the ignition on.
- With the scan tool, read DTCs and record on the repair order.
- Record the related Freeze Frame data.
- With the scan tool, erase DTCs.NOTE:
The scan tool test will not run if there are Evaporative System faults present.
- With the scan tool, perform the ELCM Forced Monitor Routine.
Did the ELCM Forced Monitor Routine pass or fail?
Passed
- Perform the INTERMITTENT CONDITION diagnostic procedure. Refer to INTERMITTENT CONDITION .
Failed
- Go To Next Step
- CHECK THE (K100) ELCM PUMP CONTROL CIRCUIT FOR A SHORT TO VOLTAGE
- Turn the ignition off.
- Disconnect the ELCM harness connector.
- Turn the ignition on.
- With a 12-volt test light connected to ground, probe the (K100) ELCM Pump Control Circuit at the ELCM harness connector.NOTE:
The test light should not be illuminated.
Is the test light illuminated?
Yes
- Repair the (K100) ELCM Pump Control Circuit for a short to voltage.
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST .
No
- Go To Next Step
- REPLACE THE ELCM
- Replace the Evaporative Leak Check Module in accordance with the Service Information.
- Turn the ignition on.
- With the scan tool, erase DTCs.NOTE:
The scan tool test will not run if there are Evaporative System faults present.
- With the scan tool, perform the ELCM Forced Monitor Routine.
Did the ELCM Forced Monitor Routine pass or fail?
Passed
- Replacing the ECLC repaired the fault.
Failed
- Go To Next Step
- CHECK RELATED PCM AND COMPONENT CONNECTIONS
- Perform any Service Bulletins that apply.
- Disconnect all PCM harness connectors.
- Disconnect all related in-line harness connections (if equipped).
- Disconnect the related component harness connectors.
- Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
- Proper connector installation.
- Damaged connector locks.
- Corrosion.
- Other signs of water intrusion.
- Weather seal damage (if equipped).
- Bent terminals.
- Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
- Terminals that have been pushed back into the connector cavity.
- Check for spread terminals and verify proper terminal tension.
Repair any conditions that are found.
- Reconnect all PCM harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
- Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
- Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
- With the scan tool, erase DTCs.
- Test drive or operate the vehicle in accordance with the when monitored and set conditions.
- With the scan tool, read DTCs.
Did the DTC return?
Yes
- Replace and program the Powertrain Control Module (PCM) in accordance with the Service Information. Refer to MODULE, POWERTRAIN CONTROL (PCM), REMOVAL AND INSTALLATION .
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST .
No
- The wiring or poor connection problem has been repaired.