WARNING: This page is about a different variant/trim than selected.
- This DTC will set if the Battery Pack Control Module (BPCM) detects the HV cable is open or problem with the battery contactor.
- This DTC may set if the 12 volt battery is weak but greater than 9.0 volts. In this case, the contactors may initially close and then re-open as system voltage drops due to the increased electrical load.