HVAC Control Systems
>>
Heating And Air Conditioning (ATC) - DTCS B1030-11 To B1053-77
>>
DTC Troubleshooting
>>
B1030-15-Evaporator Temperature Sensor-Circuit Short To Battery Or Open
>>
Set Condition
Set Condition
Evaporator Temperature Sensor Signal circuit voltage is above 4.8 volts for more than 2.5 seconds.