Heating And Air Conditioning (ATC) - DTCS B1030-11 To B1053-77
>>
DTC Troubleshooting
>>
B1030-15-Evaporator Temperature Sensor-Circuit Short To Battery Or Open
>>
Default Action
Default Action
The Evaporator Temperature Sensor value will be defaulted to -20°C (-4°F).
The A/C Compressor control will be disabled.
Loss of cooling performance.