Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- READ AND RECORD DTCS AND ENVIRONMENTAL DATA - ERASE DTCS AND CHECK FOR DTC TO RETURN WARNING:
On vehicles equipped with the high voltage system, you must thoroughly read and follow all High Voltage Safety procedures. In addition, before performing any diagnostic or service procedure near a high voltage component, you must perform the High Voltage Power Down. Failure to follow these instructions may result in possible serious or fatal injury.
Read the HIGH-VOLTAGE SAFETY PROCEDURES. Refer to HIGH VOLTAGE SAFETY PROCEDURES
When the HIGH-VOLTAGE POWER-DOWN PROCEDURE is necessary. Refer to HIGH VOLTAGE POWER DOWN .
- With the scan tool, read DTCs in all Electronic Control Units (ECUs) and record on the repair order.
- For future reference, with the scan tool, run and save a vehicle Scan Report and all related recorded data.
- With the scan tool, erase all DTCs.
- Turn the ignition off for a minimum of 10.0 seconds.
- Turn the ignition on.
- Using the When Monitored and Set Conditions above and recorded data, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read DTCs.
Did the DTC return?
Yes
- Go To 2
No
- Perform the appropriate INTERMITTENT CONDITION diagnostic procedure. Refer to TESTING FOR AN INTERMITTENT CONDITION .
- CHECK THE LOW TEMPERATURE COOLING LOOP FOR FAILURES
- Check the Low Temperature Cooling Loop for proper operation. Also check for any cooling system DTCs especially P0480-00 and P0C4A-00.
- Check cooling system for any leaks and correct mixture of coolant.
Were any problems found?
Yes
- Repair the cooling system in accordance with the Service Information.
- Perform the Hybrid Control Processor (HCP) VERIFICATION TEST. Refer to HYBRID CONTROL PROCESSOR (HCP) VERIFICATION TEST .
No
- Go To 3
- CHECK RELATED HARNESS CONNECTIONS
- Disconnect all PIM harness connectors.
- Disconnect all related in-line harness connections (if equipped).
- Disconnect the related component harness connectors.
- Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
- Proper connector installation.
- Damaged connector locks.
- Corrosion.
- Other signs of water intrusion.
- Weather seal damage (if equipped).
- Bent terminals.
- Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
- Terminals that have been pushed back into the connector cavity.
- Perform a terminal drag test on each connector terminal to verify proper terminal tension.
Repair any conditions that are found.
- Reconnect all PIM harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
- Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
- Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
- With the scan tool, erase DTCs.
- Using the recorded data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HCP DTCs.
Did the DTC return?
Yes
- Replace the Power Inverter Module (PIM) in accordance with the Service information. Refer to MODULES, HIGH VOLTAGE SYSTEM, REMOVAL AND INSTALLATION .
- Perform the Hybrid Control Processor (HCP) VERIFICATION TEST. Refer to HYBRID CONTROL PROCESSOR (HCP) VERIFICATION TEST .
No
- Perform the Hybrid Control Processor (HCP) VERIFICATION TEST. Refer to HYBRID CONTROL PROCESSOR (HCP) VERIFICATION TEST .
- Test complete.