Enabling Conditions And Possible Causes - E-Drive Modes Select Switch DTCS
WARNING: This page is about a different variant/trim than selected.
| MONITORING CONDITIONS |
| P05C8-00 ECONOMY MODE SWITCH RANGE/PERFORMANCE |
Continuous with the ignition on, battery voltage above a calibrated threshold and diagnostic monitor enabled. |
| P05C9-00-ECONOMY MODE SWITCH LOW |
| P05CA-00 ECONOMY MODE SWITCH HIGH |
| P05D1-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT LOW |
| P05D2-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT HIGH |
| P05D3-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT RANGE/PERFORMANCE |
| P05D5-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT LOW |
| P05D6-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT HIGH |
| P05D7-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT RANGE/PERFORMANCE |
| FAULT SETTING CRITERIA |
| P05C8-00 ECONOMY MODE SWITCH RANGE/PERFORMANCE |
The Hybrid Control Processor (HCP) has detected that the Hybrid drive mode switch contact is stuck closed for a time greater than a calibrated threshold. |
| P05C9-00-ECONOMY MODE SWITCH LOW |
The Hybrid Control Processor (HCP) has detected that the Hybrid drive mode switch contact is internally shorted to ground. |
| P05CA-00 ECONOMY MODE SWITCH HIGH |
The Hybrid Control Processor (HCP) has detected that the Hybrid drive mode switch contact is internally shorted to voltage. |
| P05D1-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT LOW |
The Hybrid Control Processor (HCP) has detected that the E-Drive switch contact is internally shorted to ground. |
| P05D2-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT HIGH |
The Hybrid Control Processor (HCP) has detected that the E-Drive switch contact is internally shorted to voltage. |
| P05D3-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT RANGE/PERFORMANCE |
The Hybrid Control Processor (HCP) has detected that the E-Drive switch contact is stuck closed. |
| P05D5-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT LOW |
The Hybrid Control Processor (HCP) has detected that the E-Save switch contact is internally shorted to ground. |
| P05D6-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT HIGH |
The Hybrid Control Processor (HCP) has detected that the E-Save switch contact is internally shorted to voltage. |
| P05D7-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT RANGE/PERFORMANCE |
The Hybrid Control Processor (HCP) has detected that the E-Save switch contact is stuck closed. |
| DEFAULT AND LIMP-IN ACTIONS |
| P05C8-00 ECONOMY MODE SWITCH RANGE/PERFORMANCE |
- Malfunction Indicator Lamp (MIL) on.
- Drive mode feature is not available.
- Drive mode will default to Hybrid mode.
|
| P05C9-00-ECONOMY MODE SWITCH LOW |
| P05CA-00 ECONOMY MODE SWITCH HIGH |
| P05D1-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT LOW |
| P05D2-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT HIGH |
| P05D3-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT RANGE/PERFORMANCE |
| P05D5-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT LOW |
| P05D6-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT HIGH |
| P05D7-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT RANGE/PERFORMANCE |
| POSSIBLE CAUSES |
| P05C8-00 ECONOMY MODE SWITCH RANGE/PERFORMANCE |
E-Drive Mode Select Switch |
| P05C9-00-ECONOMY MODE SWITCH LOW |
| P05CA-00 ECONOMY MODE SWITCH HIGH |
| P05D1-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT LOW |
| P05D2-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT HIGH |
| P05D3-00 DRIVER MODE SELECT SWITCH "A" CIRCUIT RANGE/PERFORMANCE |
| P05D5-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT LOW |
| P05D6-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT HIGH |
| P05D7-00 DRIVER MODE SELECT SWITCH "B" CIRCUIT RANGE/PERFORMANCE |