Diagnostic Test
- READ AND RECORD DTCS AND ENVIRONMENTAL DATA - ERASE DTCS AND CHECK FOR THE DTC TO RETURN
- With the scan tool, read DTCs in all Electronic Control Units (ECUs) and record on the repair order.
- With the scan tool, run a Vehicle Scan Report or record the Environmental Data.
- With the scan tool, erase DTCs.
- Turn the ignition off for at least 10.0 seconds.
- Turn the ignition on.
- Using the recorded Environmental Data and the When Monitored Conditions, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read DTCs.
Did the DTC return?
Yes
- Go To 2
No
- Perform the TESTING FOR AN INTERMITTENT CONDITION diagnostic procedure. Refer to TESTING FOR AN INTERMITTENT CONDITION .
- CHECK THE CONDITION OF THE LEFT FLOOR DUCT TEMPERATURE SENSOR CONNECTOR AND TERMINALS
- Turn the ignition off.
- Check the temperature sensor and harness connector and terminals for improper installation, damage, and corrosion.
Were any problems found?
Yes
- Repair the connector and terminals as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 3
- ISOLATE AND CHECK THE (C164) LEFT FLOOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO GROUND
- The ignition must be off when checking a circuit for continuity to ground.
- Isolate the circuit by disconnecting the Electronic Control Unit (ECU) and the component harness connectors containing the circuit being tested. Note: Use the wiring diagram as a guide to follow the path of the circuit. Check the disconnected connectors and related harnesses for damage, corrosion, and loose fitting terminals.
- Connect the negative lead of the Digital Volt-Ohm Meter (DVOM) to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and check for continuity between the circuit and ground.
NOTE:When back-probing a circuit at a harness connector, always use an appropriate back probing tool to prevent damage to the connector terminals.
Is there continuity between ground and the circuit being tested?
Yes
- Repair the circuit for a short to ground. Use the wiring diagram as a guide to trace the circuit and identify any in-line connectors that may help isolate the location of the short.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 4
- ISOLATE AND CHECK THE (C164) LEFT FLOOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO ANOTHER CIRCUIT AT THE HVAC MODULE HARNESS CONNECTOR
- The ignition must be off when performing a resistance check to find a short between circuits.
- Isolate the circuit by disconnecting the ECU and the component harness connectors containing the circuit being tested. Note: Use the wiring diagram as a guide to follow the path of the circuit. Check the disconnected connectors and related harnesses for damage, corrosion, and loose fitting terminals.
- Connect one lead of the DVOM to the circuit being tested at the ECU harness connector.
- With the other lead of the DVOM probe all other circuits at the ECU harness connector.
NOTE:When back-probing a circuit at a harness connector, always use an appropriate back probing tool to prevent damage to the connector terminals.
Is there continuity between the circuit being tested and any other circuit?
Yes
- Repair the circuit for a short to another circuit. Use the wiring diagram as a guide to trace the circuits and look for any in-line connectors to help isolate the location of the short.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 5
- CHECK THE LEFT FLOOR DUCT TEMPERATURE SENSOR TEMPERATURE VS RESISTANCE
Temperature Resistance -40°C (-40°F) 98, 008Ω - 103, 892Ω -30°C (-22°F) 51, 739Ω - 54, 461Ω -20°C (-4°F) 28, 469Ω - 29, 773Ω -10°C (14°F) 16, 277Ω - 16, 921Ω 0°C (32°F) 9, 632Ω - 9, 958Ω 10°C (50°F) 5, 886Ω - 6, 054Ω 20°C (68°F) 3, 703Ω - 3, 791Ω 30°C (86°F) 2, 389Ω - 2, 445Ω 40°C (104°F) 1, 576Ω - 1, 620Ω - Disconnect the Left Floor Duct Temperature Sensor harness connector.
- Note the ambient temperature. If necessary, allow the sensor to acclimate for the most accurate reading.
- Measure the resistance across the Signal and Sensor Ground terminals at the sensor.
- Compare the resistance reading to the Temperature vs. Resistance table.
Is the resistance within specification for the temperature?
Yes
- Go To 6
No
- Replace the Left Floor Duct Temperature Sensor in accordance with the Service Information. Refer to SENSOR, TEMPERATURE, AIR OUTLET, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
- CHECK RELATED HARNESS CONNECTIONS
- Disconnect all HVAC Module harness connectors.
- Disconnect all related in-line harness connections (if equipped).
- Disconnect the related component harness connectors.
- Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
- Proper connector installation.
- Damaged connector locks.
- Corrosion.
- Other signs of water intrusion.
- Weather seal damage (if equipped).
- Bent terminals.
- Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
- Terminals that have been pushed back into the connector cavity.
- Perform a terminal drag test on each connector terminal to verify proper terminal tension.
Repair any conditions that are found.
- Reconnect all HVAC Module harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
- Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
- Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC Module DTCs.
Did the DTC return?
Yes
- Replace the HVAC Module in accordance with the Service information. Refer to MODULE, HVAC, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- The wiring or poor connection problem has been repaired.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .