Home >> Jeep >> 2022 >> Gladiator Mojave, Part Time T/Case Control, Standard Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning - DTCS B11C3-00 To B11F0-15 >> DTC Troubleshooting >> B11C7-00 Front Mode Door 2 Travel Range Too Large >> Set Condition

Set Condition

NOTE:

Normal operating range is between 0.50v (0% = Air is directed to Defrost, Panel ducts, and Floor ducts) - 4.50v (100% = Air is directed to Defrost). During an actuator calibration test, the position signal may go beyond these limits temporarily.

MODE DOOR - POSITION VS SIGNAL VOLTAGE VS MODE

Position (% of Overall Door Travel) Position Signal Voltage Mode
0% - 1.47% 0.50-0.559 Defrost, Panel Ducts, and Floor Ducts
8.82% 0.853 Defrost and Panel Ducts
16.8% - 19.85% 1.147 - 1.294 Panel Ducts
33.27% - 36.95% 1.831 - 1.978 Panel Ducts and Floor Ducts
49.82% - 53.49% 2.493 - 2.640 Purge
67.65% - 71.32% 3.206 - 3.353 Floor Ducts
83.09% - 86.76% 3.824 - 3.971 Defrost and Floor Ducts
98.16 - 100% 4.42 - 4.50 Defrost