Set Condition
- One or more of the following condition is true:
- The HVAC Module detects a short to ground on one of the Recirculation Door Driver circuits for more than 30 ms.
- Voltage on the (C144) Recirculation Door Signal circuit is less than 0.03 volt for more than 1 second.