Home >> Jeep >> 2019 >> Renegade High Altitude, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1386 (948TE Automatic Transmission - DTCS P1B14-00 To U1932-00) >> DTC Troubleshooting >> P2764-00-Torque Converter Clutch Pressure Control Solenoid Control Circuit Low >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2020 Jeep Renegade. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FOR AN ACTIVE DTC 
    1. With the scan tool, read Transmission Control Module (TCM) DTCs and record on the repair order.
    2. Record the Event Data and Environmental Data.
    3. With the scan tool, erase DTCs.
    4. Using the recorded Event and Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
    5. With the scan tool, read TCM DTCs.

      Did the DTC return?

      Yes 

      • Go To  2

      No 

  2. CHECK THE RESISTANCE OF THE TORQUE CONVERTER PRESSURE CONTROL SOLENOID (7) 
    1. Turn the ignition off.
    2. Disconnect the Transmission Assembly harness connector.
    3. Measure the resistance of the Torque Converter Pressure Control Solenoid (7) at the appropriate terminals in the Transmission Assembly interface connector.

      Is the resistance of the Torque Converter Pressure Control Solenoid (7) between 4.9 and 5.9 Ohms?

      Yes 

      • Go To  3

      No 

  3. CHECK THE (T78) SOLENOID SUPPLY 1 CIRCUIT FOR AN OPEN 
    1. Disconnect the TCM harness connector.
    2. Measure the resistance of the (T78) Solenoid Supply 1 circuit between the Transmission Assembly harness connector and the TCM harness connector.

      Is the resistance below 3.0 Ohms?

      Yes 

      • Go To  4

      No 

  4. CHECK THE (T78) SOLENOID SUPPLY 1 CIRCUIT FOR A SHORT TO GROUND 
    1. Check for continuity between ground and the (T78) Solenoid Supply 1 circuit at the TCM harness connector.

      Is there continuity between ground and the (T78) Solenoid Supply 1 circuit?

      Yes 

      No 

      • Go To  5
  5. CHECK THE (T78) SOLENOID SUPPLY 1 CIRCUIT FOR A SHORT TO ANOTHER CIRCUIT 
    1. Check for continuity between the (T78) Solenoid Supply 1 circuit and all other circuits at the TCM harness connector.

      Is there continuity between the (T78) Solenoid Supply 1 circuit and any other circuits in the TCM harness connector?

      Yes 

      No 

      • Go To  6
  6. CHECK THE (T792) TORQUE CONVERTER PRESSURE CONTROL SOLENOID (7) CIRCUIT FOR AN OPEN 
    1. Measure the resistance of the (T792) Torque Converter Pressure Control Solenoid (7) circuit between the Transmission Assembly harness connector and the TCM harness connector.

      Is the resistance below 3.0 Ohms?

      Yes 

      • Go To  7

      No 

  7. CHECK THE (T792) TORQUE CONVERTER PRESSURE CONTROL SOLENOID (7) CIRCUIT FOR A SHORT TO GROUND 
    1. Check for continuity between ground and the (T792) Torque Converter Pressure Control Solenoid (7) circuit at the TCM harness connector.

      Is there continuity between ground and the (T792) Torque Converter Pressure Control Solenoid (7) circuit?

      Yes 

      No 

      • Go To  8
  8. CHECK THE (T792) TORQUE CONVERTER PRESSURE CONTROL SOLENOID (7) CIRCUIT FOR A SHORT TO ANOTHER CIRCUIT 
    1. Check for continuity between the (T792) Torque Converter Pressure Control Solenoid (7) circuit and all other circuits at the TCM harness connector.

      Is there continuity between the (T792) Torque Converter Pressure Control Solenoid (7) circuit and any other circuits in the TCM harness connector?

      Yes 

      No 

      • Go To  9
  9. CHECK RELATED HARNESS CONNECTIONS 
    1. Disconnect all TCM harness connectors.
    2. Disconnect all related in-line harness connections (if equipped).
    3. Disconnect the related component harness connectors.
    4. Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
      • Proper connector installation.
      • Damaged connector locks.
      • Corrosion.
      • Other signs of water intrusion.
      • Weather seal damage (if equipped).
      • Bent terminals.
      • Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
      • Terminals that have been pushed back into the connector cavity.
      • Perform a terminal drag test on each connector terminal to verify proper terminal tension.

      Repair any conditions that are found.

    5. Reconnect all TCM harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
    6. Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
    7. Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
    8. With the scan tool, erase DTCs.
    9. Using the recorded Event and Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
    10. With the scan tool, read TCM DTCs.

      Did the DTC return?

      Yes 

      No