When Monitored
WARNING: This page is about a different car, the 2020 Jeep Renegade. However, it is still accessible from the selected car via links, so may be relevant.
This diagnostic runs with ignition on.
- The ORC sends out a 40 mA diagnostic current on each squib circuit at power up and every 500 ms thereafter while the ignition is in on. With the ignition on, the Occupant Restraint Controller (ORC) monitors the resistance of the Left Side Curtain Squib 1 circuits.