Diagnostic Test
WARNING: This page is about a different car, the 2020 Jeep Renegade. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR AN ACTIVE DTC
- With the scan tool, read DTCs and record on the repair order.
- Record the Environmental Data.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC Module DTCs.
Did the DTC return?
Yes
- Go To 2
No
- Perform the TESTING FOR AN INTERMITTENT CONDITION procedure. Refer to TESTING FOR AN INTERMITTENT CONDITION .
- CHECK THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT FOR A SHORT TO ANOTHER CIRCUIT AT THE ELECTRONIC CONTROL UNIT (ECU) HARNESS CONNECTOR
- The ignition must be off when performing a resistance check to find a short between circuit s.
- Isolate the circuit by disconnecting the ECU and the component harness connectors containing the circuit being tested.Note: Use the wiring diagram as a guide to follow the path of the circuit. Check the disconnected connectors and related harnesses for damage, corrosion, and loose fitting terminals.
- Connect one lead of the Digital Volt-Ohm Meter (DVOM) to the circuit being tested at the ECU harness connector.
- With the other lead of the DVOM probe all other circuits at the ECU harness connector.NOTE:
When back-probing a circuit at a harness connector, always use an appropriate back probing tool to prevent damage to the connector terminals.
Is there continuity between the circuit being tested and any other circuit?
Yes
- Repair the circuit for a short to another circuit. Use the wiring diagram as a guide to trace the circuits and look for any in-line connectors to help isolate the location of the short.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 3
- CHECK THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT FOR A SHORT TO VOLTAGE
- Turn the ignition on.
- Measure voltage on the (F710) 5 Volt Reference Signal circuit at the ECU harness connector.
Is there any voltage present?
Yes
- Repair the circuit for a short to voltage. Use the wiring diagram as a guide to trace the circuits and look for any in-line connectors to help isolate the location of the short.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 4
- CHECK RELATED HARNESS CONNECTIONS
- Disconnect all HVAC Module harness connectors.
- Disconnect all related in-line harness connections (if equipped).
- Disconnect the related component harness connectors.
- Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
- Proper connector installation.
- Damaged connector locks.
- Corrosion.
- Other signs of water intrusion.
- Weather seal damage (if equipped).
- Bent terminals.
- Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
- Terminals that have been pushed back into the connector cavity.
- Perform a terminal drag test on each connector terminal to verify proper terminal tension.
Repair any conditions that are found.
- Reconnect all HVAC Module harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
- Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
- Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC Module DTCs.
Did the DTC return?
Yes
- Replace the HVAC Module in accordance with the Service information. Refer to MODULE, HVAC, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- The wiring or poor connection problem has been repaired.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .