Diagnostic Test
WARNING: This page is about a different car, the 2020 Jeep Renegade. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR AN ACTIVE DTC
- With the scan tool, read DTCs and record on the repair order.
- Record the Environmental Data.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC Module DTCs.
Did the DTC return?
Yes
- Go To 2
No
- Perform the TESTING FOR AN INTERMITTENT CONDITION procedure. Refer to TESTING FOR AN INTERMITTENT CONDITION .
- DISCONNECT THE RECIRCULATION DOOR ACTUATOR AND MEASURE THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT VOLTAGE
- Disconnect the door actuator harness connector.
- Connect the negative lead of the Digital Volt-Ohm Meter (DVOM) to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and measure the voltage between the circuit and ground.
Is the voltage above 4.8 volts?
Yes
- Replace the Recirculation Door Actuator in accordance with the Service Information. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 3
- DISCONNECT THE FRONT MODE DOOR ACTUATOR AND MEASURE THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT VOLTAGE
- Disconnect the door actuator harness connector.
- Connect the negative lead of the DVOM to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and measure the voltage between the circuit and ground.
Is the voltage above 4.8 volts?
Yes
- Replace the Mode Door Actuator in accordance with the Service Information. Refer to ACTUATOR, MODE DOOR, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 4
- DISCONNECT THE LEFT BLEND DOOR ACTUATOR AND MEASURE THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT VOLTAGE
- Disconnect the door actuator harness connector.
- Connect the negative lead of the DVOM to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and measure the voltage between the circuit and ground.
Is the voltage above 4.8 volts?
Yes
- Replace the Left Blend Door Actuator in accordance with the Service Information. Refer to ACTUATOR, BLEND DOOR, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 5
- DISCONNECT THE RIGHT BLEND DOOR ACTUATOR AND MEASURE THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT VOLTAGE
- Disconnect the door actuator harness connector.
- Connect the negative lead of the DVOM to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and measure the voltage.
Is the voltage above 4.8 volts?
Yes
- Replace the Right Blend Door Actuator in accordance with the Service Information. Refer to ACTUATOR, BLEND DOOR, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 6
- CHECK THE (F710) 5 VOLT REFERENCE SIGNAL CIRCUIT FOR A SHORT TO GROUND
- The ignition must be off when checking a circuit for continuity to ground.
- Isolate the circuit by disconnecting the Electronic Control Unit (ECU) and the component harness connectors containing the circuit being tested.Note: Use the wiring diagram as a guide to follow the path of the circuit. Check the disconnected connectors and related harnesses for damage, corrosion, and loose fitting terminals.
- Connect the negative lead of the DVOM to a known good ground.
- With the positive lead of the DVOM, probe the circuit being tested at the component harness connector and check for continuity between the circuit and ground.NOTE:
When back-probing a circuit at a harness connector, always use an appropriate back probing tool to prevent damage to the connector terminals.
Is there continuity between ground and the circuit being tested?
Yes
- Repair the circuit for a short to ground. Use the wiring diagram as a guide to trace the circuit and identify any in-line connectors that may help isolate the location of the short.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 7
- CHECK RELATED HARNESS CONNECTIONS
- Disconnect all HVAC Module harness connectors.
- Disconnect all related in-line harness connections (if equipped).
- Disconnect the related component harness connectors.
- Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
- Proper connector installation.
- Damaged connector locks.
- Corrosion.
- Other signs of water intrusion.
- Weather seal damage (if equipped).
- Bent terminals.
- Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
- Terminals that have been pushed back into the connector cavity.
- Perform a terminal drag test on each connector terminal to verify proper terminal tension.
Repair any conditions that are found.
- Reconnect all HVAC Module harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
- Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
- Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC Module DTCs.
Did the DTC return?
Yes
- Replace the HVAC Module in accordance with the Service information. Refer to MODULE, HVAC, REMOVAL AND INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- The wiring or poor connection problem has been repaired.