If the HVAC Module is replaced, the actuator positioning must be relearned to ensure proper operation. If this procedure is not performed, a DTC may be set.
With the scan tool under the Misc. Functions tab, perform the Self Learning Motors Test or the Actuator Calibration routine depending on the model year.
If a scan tool is not available, perform the following procedure:
- Turn the Ignition to the RUN position for a minimum of 10 seconds.
- Set left temperature display to 63F, (17.5C).
- Press AUTO button one time (current state is not important, just press once).
- Set left temperature display to 65F, (18.5C).
- Press AUTO Button again.
NOTE: