Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- ACTIVE DTC NOTE:
If there are any DEF Injector DTCs or DEF Supply/DEF Purge Pump DTCs present, perform the Diagnostics on those DTCs before continuing with this one.
- Turn the ignition on.
- With the scan tool, navigate to Systems Tests and actuate the DEF Injector (Dosing Valve) Actuator Test.
- With the scan tool, View DTCs.
Is the DTC active?
Yes
- Go To 2
No
- Perform the INTERMITTENT CONDITION. Refer to INTERMITTENT DTC .
- CHECK THE DEF LINE AND FITTINGS FOR RESTRICTIONS
- Turn the ignition off.
- Remove the line from the fitting at the DEF Supply Pump Assembly and DEF Injector and inspect the fittings for signs of crystallization or blockages.
Were any blockages found?
Yes
- Repair or replace the blocked lines or fittings as necessary. If P241D was also present, it will be necessary to reset the SCR Timer: Using the scan tool, Go to Misc. Functions> SCR Extend Mileage W Active Fault (and reset the Timer).
- Perform the POWERTRAIN VERIFICATION TEST. Refer to PCM VERIFICATION TEST .
No
- Replace the DEF Supply Pump Assembly in accordance with the service information. If P241D was also present, it will be necessary to reset the SCR Timer: Using the scan tool, Go to Misc. Functions> SCR Extend Mileage W Active Fault (and reset the Timer).
Perform the POWERTRAIN VERIFICATION TEST. Refer to PCM VERIFICATION TEST .