LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 2017 >> Wrangler Sahara, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 43 (Heating & Air Conditioning (ATC) - DTCS B1000 To B11CB-92) >> DTC Troubleshooting >> B11C9-00-Right Temperature Door - Travel Too Small >> Set Condition

Set Condition

WARNING: This page is about a different car, the 2017 Jeep Cherokee. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

Right Blend Door normal operating position signal voltages:

RIGHT BLEND DOOR - POSITION VS SIGNAL VOLTAGE

Door Position Minimum Position Signal Voltage Nominal Operating Position Signal Voltage Maximum Position Signal Voltage
Full Hot (0%)  0.98v 1.00v 1.02v
Full Cold (100%)  3.92v 4.00v 4.08v

The door may travel outside these values (0.98v - 4.08v) during Actuator Calibration Test. The Actuator Calibration Test is triggered when a new HVAC Module is installed, a battery disconnect has occurred, or when commanded by the scan tool.