Set Condition
WARNING: This page is about a different car, the 2017 Jeep Cherokee. However, it is still accessible from the selected car via links, so may be relevant.
- The HVAC Module learns the normal open position voltage and the normal closed position voltage of the door during an actuator calibration test. If the learned closed position (0%) is more than 1.50 volts, or learned open position (100%) is less than 3.40 volts, this DTC will set.
NOTE:
Recirculation Door normal operating position signal voltages:
RECIRCULATION DOOR - POSITION VS SIGNAL VOLTAGE
| Door Position | Minimum Position Signal Voltage | Nominal Operating Position Signal Voltage | Maximum Position Signal Voltage |
|---|---|---|---|
| Outside Air (0%) | 1.10v | 1.13v | 1.15v |
| Recirculation (100%) | 3.80v | 3.88v | 3.95v |
The door may travel outside these values (1.10v - 3.95v) during Actuator Calibration Test. The Actuator Calibration Test is triggered when a new HVAC Module is installed, a battery disconnect has occurred, or when commanded by the scan tool.