Door Open Indicator Always On
After performing the initial test, the doors open indicator, located on the Instrument Panel Cluster, is always on.
| 0 | PRELIMINARY CHECKS | Result OK | Result Not OK | Action |
| Check the correct closure of the four doors | Continue to Step 1 | Doors not properly closed | Ensure the doors close properly | |
| 1 | CHECK WITH DIAGNOSTIC TOOL | Result OK | Result Not OK | Action |
| With the diagnostic scan tool, check in the Instrument Panel Cluster the absence of errors and the presence of the parameters | Continue to Step 2 | 1. the scan tool cannot connect to the instrument panel cluster 2. presence of errors |
1. Continue to Step 2 2. Proceed as indicated by the diagnostic tool |
|
| 2 | CHECK WITH DIAGNOSTIC TOOL | Result OK | Result Not OK | Action |
| With the diagnostic scan tool, check in the Body Control Module (BCM) for the absence of errors and the variation of the parameter for the state of the doors | Continue to Step 4 | The parameter values do not change | Continue to Step 3 | |
| 3 | CHECK ELECTRICAL CONNECTIONS | Result OK | Result Not OK | Action |
| Check the operation of the switches on the door motors Check the ground insulation of the connection between the switches and door inputs to the BCM |
Continue to Step 4 | 1. Switch defective 2. Wiring with imperfect ground insulation |
1. Replace switch 2. Restore the wiring insulation |
|
| 4 | CHECK WITH ACTIVE DIAGNOSIS | Result OK | Result Not OK | Action |
| With the diagnostic scan tool under Instrument Panel Cluster, check in "Active Diagnosis" the correct activation, check the open doors light | Continue to Step 5 | The light check doors open is not activated | Replace instrument panel cluster | |
| 5 | CHECK PROPER OPERATION | Result OK | Result Not OK | Action |
| Verify that the fault is no longer present | Diagnostic complete | Anomaly persists | Replace the Body Control Module |