LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 2017 >> Renegade Trailhawk >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Cluster (Service Information) >> Diagnosis And Testing >> Clock Does Not Work

Clock Does Not Work

When the ignition key is turned to the on position, the clock does not display or displays incorrectly.

1 CHECK INSTRUMENT PANEL FEATURES Result OK Result Not OK Action
  Verify:
The display shows the correct time
You can adjust the time
The clock time advances
Diagnostic complete 1. The time displayed is not correct
2. You can not adjust the time
3. The clock time does not advance
1. Set the time correctly
2. Continue to Step 2
3. Continue to Step 3
2 CHECK WITH DIAGNOSTIC TOOL Result OK Result Not OK Action
  Connect the diagnostic scan tool to the DLC.
Verify the absence of anomalies on the instrument panel cluster.
Continue to Step 3 Presence of errors Proceed as indicated by the diagnostic tool
3 CHECK WITH DIAGNOSTIC TOOL Result OK Result Not OK Action
  With the diagnostic scan tool still connected to the DLC, verify the functionality of the display via active diagnosis. Diagnostic complete display faulty Replace the instrument panel cluster