Diagnostic Test
- CHECK IF DTC IS ACTIVE
- PERFORM HVAC ACTUATOR CALIBRATION TEST
- CHECK THE RECIRCULATION DOOR ACTUATOR
Courtesy of CHRYSLER GROUP, LLC
- Turn the ignition off to the lock position.
- Disconnect the A/C Heater Control C1 harness connector.
- Measure the resistance between the (C32) Recirculation Door Driver circuit and the (C34) Common Door Driver circuit.
Is the resistance 38.0 Ohms (± 5.0 Ohms)?
Yes
- Replace and program the A/C Heater Control in accordance with the Service Information. Refer to CONTROL, A/C AND HEATER, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 4
- CHECK THE (C32) RECIRCULATION DOOR DRIVER CIRCUIT FOR AN OPEN
- Turn the ignition off to the lock position.
- Disconnect the Recirculation Door Actuator harness connector.
- Measure the resistance of the (C32) Recirculation Door Driver circuit between the A/C Heater Control C1 harness connector and the Recirculation Door Actuator harness connector.
Is the resistance above 1.0 Ohm?
Yes
- Repair the (C32) Recirculation Door Driver circuit for an open or high resistance.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 5
- CHECK THE (C34) COMMON DOOR DRIVER CIRCUIT FOR AN OPEN
- Measure the resistance of the (C34) Common Door Driver circuit between the A/C Heater Control C1 harness connector and the Recirculation Door Actuator harness connector.
Is the resistance above 1.0 Ohm?
Yes
- Repair the (C34) Common Door Driver circuit for an open or high resistance.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Replace the Recirculation Door Actuator in accordance with the Service Information. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- Measure the resistance of the (C34) Common Door Driver circuit between the A/C Heater Control C1 harness connector and the Recirculation Door Actuator harness connector.
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.