LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 2014 >> Wrangler Sahara, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 123 (Body Control Module (BCM) - DTCS B1812-2A To U1433-24) >> DTC Troubleshooting >> B182C-11-All Door Lock Control - Circuit Short To Ground >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2016 Dodge Journey and 2015 Dodge Journey. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FOR AN ACTIVE DTC 
    1. Turn the ignition on.
    2. Lock and unlock the doors.
    3. With the scan tool, read DTCs.

      Does the scan tool display this DTC as active?

      Yes 

      • Go To  2

      No 

      • Test complete. The condition or conditions that originally set this DTC are not present at this time. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals and correct pin tension.
      • Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .
  2. CHECK EACH MOTOR ON THE (P777) DOOR LOCK CONTROL CIRCUIT FOR A SHORT TO GROUND 
    NOTE:

    Using the wiring diagram as a guide, disconnect each component on the circuit one at a time and check for an active DTC.

    1. Turn the ignition off.
    2. Disconnect one of the Door Lock Motors on the circuit.
    3. Turn the ignition on.
    4. Lock and unlock the doors.
    5. With the scan tool, read DTCs.

      Does the scan tool display this DTC as active?

      Yes 

      • Repeat this step for all the Door Lock Motors on the circuit. Once all the motors are disconnected: Go To  3

      No 

      • Replace the Door Lock Motor/Latch causing the short to ground condition in accordance with the Service Information. Refer to LATCH, DOOR, REMOVAL .
      • Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .
  3. CHECK THE (P777) DOOR LOCK CONTROL CIRCUIT FOR A SHORT TO GROUND 
    1. Turn the ignition off.
    2. Disconnect the BCM F harness connector.
    3. Measure the resistance between ground and the (P777) Door Lock Control circuit.

      Is the resistance above 10k Ohms?

      Yes 

      No 

      • Repair the short to ground in the (P777) Door Lock Control circuit.
      • Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .