Diagnostic Test
WARNING: This page is about a different car, the 2016 Dodge Journey and 2015 Dodge Journey. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK IF DTC IS ACTIVE
- PERFORM HVAC ACTUATOR CALIBRATION TEST
- CHECK THE (C52) PASSENGER BLEND DOOR DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
Courtesy of CHRYSLER GROUP, LLC
- Turn the ignition off to the lock position.
- Disconnect the A/C Heater Module C1 harness connector.
- Disconnect the Passenger Blend Door Actuator harness connector.
- Ignition on, engine not running.
- Measure the voltage of the (C52) Passenger Blend Door Driver circuit.
Is there any voltage present?
Yes
- Repair the (C52) Passenger Blend Door Driver circuit for a short to voltage.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 4
- CHECK THE (C807) COMMON DOOR DRIVER 2 CIRCUIT FOR A SHORT TO VOLTAGE
- Measure the voltage of the (C807) Common Door Driver 2 circuit.
Is there any voltage present?
Yes
- Repair the (C807) Common Door Driver 2 circuit for a short to voltage.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 5
- Measure the voltage of the (C807) Common Door Driver 2 circuit.
- CHECK THE PASSENGER BLEND DOOR ACTUATOR
- Replace the Passenger Blend Door Actuator in accordance with the Service Information. Refer to ACTUATOR, BLEND DOOR, FRONT, REMOVAL .
- With the scan tool, erase HVAC DTCs and perform the HVAC Actuator Calibration Test.
Did this DTC reset?
Yes
- Replace and program the A/C Heater Module in accordance with the Service Information. Refer to MODULE, HVAC .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.