Diagnostic Test
WARNING: This page is about a different car, the 2016 Dodge Journey and 2015 Dodge Journey. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR RELATED DTCS
- Ignition on, engine not running.
- Using the scan tool, read HVAC DTCs.
Are there any Door Control Circuit Open, Performance, or Short to Ground or Voltage DTCs present?
Yes
- Refer to DIAGNOSTIC CODE INDEX and perform the appropriate diagnostic procedure.
No
- Go To 2
- CHECK IF DTC IS ACTIVE
- PERFORM HVAC ACTUATOR CALIBRATION TEST
- CHECK THE REAR MODE DOOR
- Remove the Rear Mode Door Actuator and check the Rear Mode Door for binding and full travel. Refer to ACTUATOR, MODE DOOR, REAR, REMOVAL
.
Were there any problems found?
Yes
- Repair or replace the Rear Mode Door as necessary in accordance with the Service Information. Refer to HOUSING, A/C AND HEATER, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 5
- Remove the Rear Mode Door Actuator and check the Rear Mode Door for binding and full travel. Refer to ACTUATOR, MODE DOOR, REAR, REMOVAL
.
- CHECK THE REAR MODE DOOR ACTUATOR
- Replace the Rear Mode Door Actuator in accordance with the Service Information. Refer to ACTUATOR, MODE DOOR, REAR, REMOVAL .
- Using the scan tool, erase HVAC DTCs.
- Using the scan tool, perform the HVAC Actuator Calibration Test.
Did this DTC reset during HVAC Actuator Calibration Test?
Yes
- Replace and program the A/C Heater Module in accordance with the Service Information. Refer to MODULE, HVAC .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- Using the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.