Possible Causes
| Possible Causes |
|---|
| 5-VOLT SUPPLY CIRCUIT SHORTED TO VOLTAGE |
| 5-VOLT SUPPLY CIRCUIT SHORTED TO GROUND |
| 5-VOLT SUPPLY CIRCUIT SHORTED TO THE CKP SENSOR GROUND CIRCUIT |
| 5-VOLT SUPPLY CIRCUIT OPEN/HIGH RESISTANCE |
| CKP SIGNAL CIRCUIT SHORTED TO VOLTAGE |
| CKP SIGNAL CIRCUIT SHORTED TO GROUND |
| CKP SIGNAL CIRCUIT SHORTED TO THE CKP SENSOR GROUND CIRCUIT |
| CKP SIGNAL CIRCUIT OPEN/HIGH RESISTANCE |
| CKP SENSOR GROUND CIRCUIT OPEN/HIGH RESISTANCE |
| CRANKSHAFT POSITION SENSOR |
| POWERTRAIN CONTROL MODULE (PCM) |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Refer to PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE .