Manual Procedure
- Make sure the ignition switch is in the Run position and the engine is running.
- If the roof is in a position other than fully closed, press the roof switch center button for less than 500 milliseconds (one-half second) to fully close the roof.
- With the roof fully closed, turn the ignition off, then restart the engine (ignition switch in the Run position). Within five seconds after the restart, press and hold the roof switch center button for more than 20 seconds and do not release until the following automated roof cycles are complete.
- Front of roof will close (then stall).
- Rear of roof will cose (then stall).
- Rear of roof will open.
- Rear of roof will close.
- Rear of roof vents (approx two inches).
- Front of roof will open.
- Front of roof will close.
- Rear of roof closes from vent.
- Once all movement has stopped, release the roof switch center button. The roof system initialization is now complete.