Diagnostic Test
- TRANSFER CASE POSITION SENSOR SWITCH VOLTAGE LESS THAN 0.2 VOLTS
- TRANSFER CASE SELECTOR SWITCH
- Turn the ignition off to the lock position
- Disconnect the Transfer Case Selector Switch harness connector.
- Connect a jumper wire between the (K77) Transfer Case Position Sensor Input circuit and the (Z940) Ground circuit in the Transfer Case Selector Switch harness connector.
- Ignition on, engine not running.
- With the scan tool, read the Transfer Case Position Sensor Switch voltage.
- The switch voltage should be approximately 5.0 volts.
Does the voltage display as described?
Yes
- Replace the Transfer Case Selector Switch.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Go to step 3
- (K77) TRANSFER CASE POSITION SENSOR INPUT CIRCUIT SHORTED TO GROUND
- Turn the ignition off to the lock position
- Disconnect the CCN C3 harness connector.
- Measure the resistance between ground and the (K77) Transfer Case Position Sensor Input circuit.
Is the resistance less than 5.0 Ohms?
Yes
- Repair the (K77) Transfer Case Position Sensor Input circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Go to step 4
- (K77) TRANSFER CASE POSITION SENSOR INPUT CIRCUIT OPEN
- Measure the resistance of the (K77) Transfer Case Position Sensor Input circuit between the Transfer Case Selector Switch harness connector and the CCN C3 harness connector.
Is the resistance greater than 5.0 Ohms?
Yes
- Repair the (K77) Transfer Case Position Sensor Input circuit for an open.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Go to step 5
- Measure the resistance of the (K77) Transfer Case Position Sensor Input circuit between the Transfer Case Selector Switch harness connector and the CCN C3 harness connector.
- (Z940) GROUND CIRCUIT OPEN
- Measure the resistance of the (Z940) Ground circuit between the Transfer Case Selector Switch harness connector and the CCN C3 harness connector.
Is the resistance above 5.0 Ohms?
Yes
- Repair the (Z940) Ground circuit for an open.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Replace the CCN in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
- Measure the resistance of the (Z940) Ground circuit between the Transfer Case Selector Switch harness connector and the CCN C3 harness connector.
- INTERMITTENT WIRING AND CONNECTORS
- The conditions necessary to set this DTC are not present at this time.
- Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- While monitoring the scan tool data relative to this circuit, wiggle test the wiring and connectors.
- Look for the data to change or for the DTC to reset during the wiggle test.
- While monitoring the scan tool data relative to this circuit, move the selector switch to each position several times.
- Look for the data to change other than as expected or for the DTC to reset.
Were any problems found?
Yes
- Repair as necessary.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Test complete.