Home >> Jeep >> 2008 >> Compass Limited, AWD, Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Cluster - Electrical Diagnostics >> Instrument Cluster - Electrical Diagnostics >> DTC Troubleshooting >> U113B-Lost Communication With Switch Bank Module >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR AN ACTIVE DTC 

    Turn the ignition on.

    With the scan tool, record and erase DTCs.

    Wait 30 seconds.

    With the scan tool, read DTCs.

    Does the scan tool display: U113B-LOST COMMUNICATION WITH SWITCH BANK MODULE? 

    Yes 

    1. Go To  2.

    No 

    1. The condition that caused this code to set is not present at this time. Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also inspect the related connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  2. (D506) LIN BUS CIRCUIT OPEN 
    Fig 1: Measuring Voltage Of (D506) LIN BUS Circuit
    GC0053433Courtesy of CHRYSLER LLC

    Turn the ignition off.

    Disconnect the Switch Bank harness connector.

    Turn the ignition on.

    Measure the voltage of the (D506) LIN BUS circuit.

    Is the voltage above 5 volts? 

    Yes 

    1. Go To  3.

    No 

    1. Repair the (D506) LIN BUS circuit for an open.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  3. (A935) FUSED B+ CIRCUIT OPEN 
    Fig 2: Measuring Voltage Of (A935) Fused B+ Circuit
    GC0053434Courtesy of CHRYSLER LLC

    Measure the voltage of the (A935) Fused B+ circuit.

    Is the voltage above 10 volts? 

    Yes 

    1. Go To  4.

    No 

    1. Repair the (A935) Fused B+ circuit for an open.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  4. (Z940) GROUND CIRCUIT OPEN 
    Fig 3: Measuring Resistance Between Ground And (Z940) Ground Circuit
    GC0053435Courtesy of CHRYSLER LLC

    Measure the resistance between ground and the (Z940) Ground circuit.

    Is the resistance below 10K ohms? 

    Yes 

    1. Replace the Switch Bank in accordance with the service information.
    2. Perform BODY VERIFICATION TEST - VER 1 .

    No 

    1. Repair the (Z940) ground circuit for an open.
    2. Perform BODY VERIFICATION TEST - VER 1 .