WARNING: This page is about a different variant/trim than selected.
- Verify that MDS bores are free of debris, before solenoid installation.
- Install MDS solenoid(s) (3) fully into block.
- Install hold down bolt (2) and tighten to 11 N.m (97 in. lbs.).
- Reconnect the MDS wiring harness to the solenoid(s) (3).
- Install foam insulator pad (1) if removed.
- Install the intake manifold. See INSTALLATION .