Diagnostic Procedure
DIAGNOSTIC INFORMATION AND PROCEDURES CHART (NO BUS IN VF DISPLAY)
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 | Turn the ignition off. Inspect the #24 fuse in the Power Distribution Center. If the fuse is open, replace with proper rated fuse. Turn the ignition on for one minute. Turn the ignition off. Inspect the #24 fuse in the Power Distribution Center. Is the fuse open? Yes --> Repair the Fused B(+) circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1 . No --> Go To 2 |
All |
| 2 | Turn the ignition off. Disconnect the Instrument Cluster C1 harness connector. Check connectors - Clean/repair as necessary. Measure the voltage between the Fused B(+) circuit and ground. Is the voltage above 10.5 volts? Yes --> Replace and configure the Instrument Cluster in accordance with the Service Information. Perform BODY VERIFICATION TEST - VER 1 . No --> Repair the Fused B(+) circuit for an open. Perform BODY VERIFICATION TEST - VER 1 . |
All |