Fig 1: Outboard IP Air Outlets-R and I
GC0028329Courtesy of DAIMLERCHRYSLER CORP.
  1. Position the outboard instrument panel air outlet(s) (2) into the instrument panel top cover (3).
    NOTE: Make sure that the air outlet is properly aligned to the instrument panel opening and that the foam seal on the outlet is properly installed.
  2. Install the three screws (1) that secure the instrument panel air outlets to the top cover. Tighten the screws to 2 N.m (17 in. lbs.).
  3. Install the instrument panel ducts into the instrument panel (Refer to HEATING & AIR CONDITIONING/DISTRIBUTION/DUCTS-INSTRUMENT PANEL - INSTALLATION) .
  4. Install the instrument panel (Refer to BODY/INSTRUMENT PANEL/INSTRUMENT PANEL ASSEMBLY - INSTALLATION) .