LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 2005 >> Wrangler Rubicon, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 562 (HVAC Systems (Service Information)) >> Distribution >> HVAC Housing >> Assembly >> Air Inlet Housing

Air Inlet Housing

WARNING: This page is about a different car, the 2005 Jeep Grand Cherokee. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.
Fig 1: Air Inlet Housing D and A
GC0028348Courtesy of DAIMLERCHRYSLER CORP.
  1. Position the recirculation-air door (4) into the air inlet housing (1).
    CAUTION: Make sure that the recirculation-air door pivot shaft is properly seated in the pivot seats located on the air inlet housing.
  2. Install the recirculation door actuator (3) onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator output shaft with those on the recirculation door pivot shaft (Refer to HEATING & AIR CONDITIONING/CONTROLS/ACTUATOR-RECIRCULATION DOOR - INSTALLATION) .
  3. Install the two screws (2) that secure the recirculation door actuator to the air inlet housing. Tighten the screws to 2 N.m (17 in. lbs.).
  4. Install the air inlet housing onto the HVAC housing (Refer to HEATING & AIR CONDITIONING/DISTRIBUTION/HOUSING-HVAC - AIR INLET HOUSING - INSTALLATION) .