Diagnostic Procedure
WARNING: This page is about a different car, the 2005 Jeep Liberty. However, it is still accessible from the selected car via links, so may be relevant.
DIAGNOSTIC PROCEDURE - TEMP DISPLAY INOPERATIVE OR WRONG
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 |
NOTE:
Diagnose and repair any PCM, EVIC, or Communication DTCs before proceeding with this test.
NOTE:
The Ambient Temperature Sensor is hardwired to the PCM. Ambient temperature information is transmitted to the EVIC via the PCI Bus. Turn the ignition off.Disconnect the Ambient Temperature Sensor harness connector.Measure the resistance of the Ambient Temperature Sensor using the following temperature/resistance values:10°C (50°F) Sensor Resistance = 17.99 - 21.81 Kilohms20°C (68°F) Sensor Resistance = 11.37 - 13.61 Kilohms25°C (77°F) Sensor Resistance = 9.12 - 10.88 Kilohms30°C (86°F) Sensor Resistance = 7.37 - 8.75 Kilohms40°C (104°F) Sensor Resistance = 4.90 - 5.75 Kilohms50°C (122°F) Sensor Resistance = 3.33 - 3.88 KilohmsIs the Ambient Temperature Sensor resistance measurement between the min/max specifications?Yes --> Go To 2No --> Replace the Ambient Temperature Sensor.
NOTE:
After any repair for an Ambient Temperature Sensor problem, the vehicle must be driven over 5 kilometers (3 miles) above 40 km/h (25 MPH) to update the EVIC display. Perform BODY VERIFICATION TEST - VER 1 . |
All |
| 2 | Perform the EVIC self test . Turn the ignition off. Press and hold the C/T and Reset buttons. Turn the ignition on.
NOTE:
The self test can also be performed using the DRBIII®. Observe the EVIC display at the conclusion of the self test. Does the EVIC display "PASSED SELF TEST"? Yes --> Test Complete. No --> Replace the EVIC in accordance with the Service Information. Perform BODY VERIFICATION TEST - VER 1 . |
All |