Liftgate Ajar Indicator Stays Illuminated With Liftgate Closed
Turn ignition switch to OFF position. Disconnect negative battery cable. Disconnect liftgate ajar switch harness connector. Check continuity between terminals No. 1 (Black wire) and No. 2 (Tan/Black wire) at liftgate ajar switch harness connector. If no continuity exists, repair short to ground in Tan/Black wire between instrument cluster and liftgate ajar switch. If continuity exists, replace liftgate ajar switch.