Code 47
WARNING: This page is about a different car, the 1995 Jeep Grand Cherokee. However, it is still accessible from the selected car via links, so may be relevant.
DRB displays CHARGING SYSTEM VOLTAGE TOO LOW. Condition is: battery voltage sense input less than target charging voltage during engine operation and no significant change detected in battery voltage during active test of generator output.