DTC P0034-11: Turbocharger/supercharger Bypass Valve "A" Control Circuit Low - Circuit short to ground: Action
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
- Refer to the appropriate System Wiring Diagram(s) and check the turbine bypass control actuator circuit for short circuit to ground
- Inspect connectors for signs of water ingress, and pins for damage and/or corrosion
- Check and install a new turbine bypass control actuator as required
- Using the Jaguar Land Rover approved diagnostic equipment, clear the DTCs and retest