LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2023 >> XF R-Dynamic SE >> Repair and Diagnosis >> External Pages >> Different car >> Section 18 (Electronic Engine Controls - V6 S/C 3.0L Petrol -- XE (X760)) >> Electronic Engine Controls - V6 S/C 3.0 L Petrol >> Right Variable Valve Timing Oil Control Solenoid >> Removal And Installation >> Removal

Removal And Installation: Removal

WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
  • This procedure contains some variation in the illustrations depending on the vehicle specification, but the essential information is always correct.
  • This procedure contains illustrations showing certain components removed to provide extra clarity.
  1. Remove the Air Cleaner Outlet Pipe T-Connector.

    Refer to: Air Cleaner Outlet Pipe T-Connector (Removal and Installation).

  2. Disconnect the 2 electrical connectors and remove the 4 bolts.
    G11308523
  3. Evenly and progressively, remove the variable valve timing oil control solenoids.
    CAUTION: Evenly and progressively remove.
    G11308524
  4. Disconnect the startup battery ground cable.

    Refer to: Battery Disconnect and Connect (General Procedures).

  5. Raise and support the vehicle on a suitable 2 post lift.

    Refer to: Lifting .